Upright Sprinklers
Upright Sprinklers are fire-suppression devices designed for installation on piping where obstructions or open structural elements prevent the use of pendent sprinklers.
The deflector is positioned above the orifice, allowing water to discharge upward and then spread in a circular pattern to provide uniform coverage across open areas.
These sprinklers are widely used in warehouses, parking garages, industrial plants, manufacturing facilities and spaces with exposed ceilings. Available in multiple temperature ratings, response types, K-factors and finishes to fit diverse fire-protection system designs.
Upright Sprinklers Categories
Fire Fighting Equipment
Fire Sprinkler Systems
Upright Type Sprinklers
Standard Response Sprinklers
Quick Response Sprinklers
Industrial Fire Protection Components
Upright Sprinklers Key Features
best upright fire sprinklers for warehouses
K-factor upright sprinkler for industrial buildings
upright sprinkler head for high-ceiling structures
fire sprinkler heads for factories and plants
how to choose upright vs pendent sprinkler
upright fire sprinkler head price list
UL/FM approved upright sprinkler supplier
high-temperature upright fire sprinkler head
upright sprinkler for parking garages
corrosion-resistant upright sprinkler heads
sprinkler head with 1/2 inch NPT thread
sprinkler head with 3/4 inch NPT thread
industrial upright sprinkler for fire safety systems
upright sprinkler
upright fire sprinkler
upright sprinkler head
fire sprinkler head
fire sprinkler system
standard response upright sprinkler
quick response upright sprinkler
K-factor sprinkler
industrial fire sprinkler
warehouse fire sprinkler
buy upright fire sprinkler
upright sprinkler supplier
upright fire sprinkler price
fire sprinkler heads wholesale
industrial sprinkler heads sale
UL listed upright sprinkler dealer
- fire sprinkler head online purchase
fire suppression systems
fire safety equipment
automatic sprinkler systems
sprinkler deflector pattern
heat-sensitive bulb sprinkler
warehouse fire protection
commercial fire sprinklers
fire sprinkler distributor
sprinkler activation temperature
wet pipe fire system
exposed ceiling fire sprinklers
industrial fire hazard protection
fire safety sprinkler head manufacturer
warehouse sprinkler system parts
K-factor fire sprinkler head
upright fire sprinkler distributors
upright type fire sprinkler
brass upright sprinkler
chrome upright sprinkler
fire suppression sprinkler
K5.6 upright sprinkler
K8.0 upright sprinkler
UL listed upright sprinkler
FM approved upright sprinkler
sprinkler head for warehouse
industrial fire protection sprinkler
sprinkler head for exposed ceilings
dry pipe system upright sprinkler
standard response sprinkler head
quick response sprinkler head
NFPA fire sprinkler head



Upright Sprinklers Description
Standard: ANSI/ UL 199
K factor: K 5.6, K 8.0
Response: Standard with 5 mm glass bulb
Thread: NPT/ BSPT
W. pressure: 175 psi (1.21 MPa)
Finish: Rough brass/ chrome plated/ white
Technical Specifications
Available K-Factors
K5.6 (80 metric)
K8.0 (115 metric)
K11.2 (160 metric)
K14.0 (200 metric)
Temperature Ratings
| Temperature Rating | Bulb Color | °C | °F |
| Ordinary | Orange | 57°C | 135°F |
| Ordinary | Red | 68°C | 155°F |
| Intermediate | Yellow | 79°C | 175°F |
| Intermediate | Green | 93°C | 200°F |
| High | Blue | 141°C | 286°F |
| Extra High | Purple | 182°C | 360°F |
Response Types
Standard Response (SR)
Quick Response (QR)
Thread Sizes
1/2″ NPT
3/4″ NPT
1″ NPT (Heavy Duty Models)
Material & Finish
Material:
Brass body
Stainless steel or phosphor bronze deflector
Glass bulb with heat-sensitive liquid
Finishes:
Natural Brass
Chrome Plated
White Painted
Custom RAL colors available (on request)
Working Pressure
Maximum Working Pressure: 175 psi (12 bar)
Factory Hydrostatic Test: 500 psi (34.5 bar)
Water Distribution Pattern
Deflector designed for upward discharge
Uniform hemispherical spray pattern
Optimized for high-ceiling and obstruction-rich environments
Installation Guidelines
Install per NFPA 13 or relevant local codes
Upright orientation only
Suitable for wet, dry, and pre-action systems
Maintain proper distance from obstructions
Ensure correct temperature rating based on ambient conditions
Upright Sprinklers (Sizes + SKU Codes)

| Model | K-Factor | Thread Size | Temp Rating | Finish | SKU Code |
| Upright Sprinkler – QR | K5.6 | 1/2″ NPT | 57°C | Brass | USK-56-12-57-BR |
| Upright Sprinkler – QR | K5.6 | 1/2″ NPT | 68°C | Chrome | USK-56-12-68-CR |
| Upright Sprinkler – SR | K5.6 | 3/4″ NPT | 79°C | Brass | USK-56-34-79-BR |
| Upright Sprinkler – SR | K8.0 | 3/4″ NPT | 93°C | Red | USK-80-34-93-RD |
| Upright Sprinkler – Industrial | K11.2 | 3/4″ NPT | 141°C | Brass | USK-112-34-141-BR |
| Upright Sprinkler – Heavy Duty | K14.0 | 1″ NPT | 182°C | Bronze | USK-140-10-182-BZ |
Sample Time: Available in 5-10 days for different items.
Drawing Format: CAD / PDF / DWG / IGS / STEP.
Packaging: Standard package, Carton box or Pallet, As per customized specifications