welcome to kaizen metals india
upright sprinklers

Upright Sprinklers

Upright Sprinklers are fire-suppression devices designed for installation on piping where obstructions or open structural elements prevent the use of pendent sprinklers.

The deflector is positioned above the orifice, allowing water to discharge upward and then spread in a circular pattern to provide uniform coverage across open areas.

These sprinklers are widely used in warehouses, parking garages, industrial plants, manufacturing facilities and spaces with exposed ceilings. Available in multiple temperature ratings, response types, K-factors and finishes to fit diverse fire-protection system designs.

Upright Sprinklers Categories

  • Fire Fighting Equipment

  • Fire Sprinkler Systems

  • Upright Type Sprinklers

  • Standard Response Sprinklers

  • Quick Response Sprinklers

  • Industrial Fire Protection Components

Upright Sprinklers Key Features

  • best upright fire sprinklers for warehouses

  • K-factor upright sprinkler for industrial buildings

  • upright sprinkler head for high-ceiling structures

  • fire sprinkler heads for factories and plants

  • how to choose upright vs pendent sprinkler

  • upright fire sprinkler head price list

  • UL/FM approved upright sprinkler supplier

  • high-temperature upright fire sprinkler head

  • upright sprinkler for parking garages

  • corrosion-resistant upright sprinkler heads

  • sprinkler head with 1/2 inch NPT thread

  • sprinkler head with 3/4 inch NPT thread

  • industrial upright sprinkler for fire safety systems

  • upright sprinkler

  • upright fire sprinkler

  • upright sprinkler head

  • fire sprinkler head

  • fire sprinkler system

  • standard response upright sprinkler

  • quick response upright sprinkler

  • K-factor sprinkler

  • industrial fire sprinkler

  • warehouse fire sprinkler

  • buy upright fire sprinkler

  • upright sprinkler supplier

  • upright fire sprinkler price

  • fire sprinkler heads wholesale

  • industrial sprinkler heads sale

  • UL listed upright sprinkler dealer

  • fire sprinkler head online purchase
  • fire suppression systems

  • fire safety equipment

  • automatic sprinkler systems

  • sprinkler deflector pattern

  • heat-sensitive bulb sprinkler

  • warehouse fire protection

  • commercial fire sprinklers

  • fire sprinkler distributor

  • sprinkler activation temperature

  • wet pipe fire system

  • exposed ceiling fire sprinklers

  • industrial fire hazard protection

  • fire safety sprinkler head manufacturer

  • warehouse sprinkler system parts

  • K-factor fire sprinkler head

  • upright fire sprinkler distributors

  • upright type fire sprinkler

  • brass upright sprinkler

  • chrome upright sprinkler

  • fire suppression sprinkler

  • K5.6 upright sprinkler

  • K8.0 upright sprinkler

  • UL listed upright sprinkler

  • FM approved upright sprinkler

  • sprinkler head for warehouse

  • industrial fire protection sprinkler

  • sprinkler head for exposed ceilings

  • dry pipe system upright sprinkler

  • standard response sprinkler head

  • quick response sprinkler head

  • NFPA fire sprinkler head

upright sprinklers
upright type sprinkler
upright type sprinkler

Upright Sprinklers Description

Standard: ANSI/ UL 199
K factor: K 5.6, K 8.0
Response: Standard with 5 mm glass bulb
Thread: NPT/ BSPT
W. pressure: 175 psi (1.21 MPa)
Finish: Rough brass/ chrome plated/ white

Technical Specifications

Available K-Factors
  • K5.6 (80 metric)

  • K8.0 (115 metric)

  • K11.2 (160 metric)

  • K14.0 (200 metric)

Temperature Ratings
Temperature RatingBulb Color°C°F
OrdinaryOrange57°C135°F
OrdinaryRed68°C155°F
IntermediateYellow79°C175°F
IntermediateGreen93°C200°F
HighBlue141°C286°F
Extra HighPurple182°C360°F
Response Types
  • Standard Response (SR)

  • Quick Response (QR)

Thread Sizes
  • 1/2″ NPT

  • 3/4″ NPT

  • 1″ NPT (Heavy Duty Models)

Material & Finish

Material:

  • Brass body

  • Stainless steel or phosphor bronze deflector

  • Glass bulb with heat-sensitive liquid

Finishes:

  • Natural Brass

  • Chrome Plated

  • White Painted

  • Custom RAL colors available (on request)

Working Pressure
  • Maximum Working Pressure: 175 psi (12 bar)

  • Factory Hydrostatic Test: 500 psi (34.5 bar)

Water Distribution Pattern
  • Deflector designed for upward discharge

  • Uniform hemispherical spray pattern

  • Optimized for high-ceiling and obstruction-rich environments

Installation Guidelines
  • Install per NFPA 13 or relevant local codes

  • Upright orientation only

  • Suitable for wet, dry, and pre-action systems

  • Maintain proper distance from obstructions

  • Ensure correct temperature rating based on ambient conditions

Upright Sprinklers (Sizes + SKU Codes)

pendent sprinklers
ModelK-FactorThread SizeTemp RatingFinishSKU Code
Upright Sprinkler – QRK5.61/2″ NPT57°CBrassUSK-56-12-57-BR
Upright Sprinkler – QRK5.61/2″ NPT68°CChromeUSK-56-12-68-CR
Upright Sprinkler – SRK5.63/4″ NPT79°CBrassUSK-56-34-79-BR
Upright Sprinkler – SRK8.03/4″ NPT93°CRedUSK-80-34-93-RD
Upright Sprinkler – IndustrialK11.23/4″ NPT141°CBrassUSK-112-34-141-BR
Upright Sprinkler – Heavy DutyK14.01″ NPT182°CBronzeUSK-140-10-182-BZ

Sample Time: Available in 5-10 days for different items.

Drawing Format: CAD / PDF / DWG / IGS / STEP.

Packaging: Standard package, Carton box or Pallet, As per customized specifications

Shipping: DHL, FEDEX, UPS and By Sea or as per client’s requirements.

Any kind of Upright Sprinkler can be developed and supplied exactly as per customer specifications.